Call 08048986924 86% Response Rate

our range

Air Dryers

Our range of products include compressed air dryer, refrigerated air dryers and desiccant air dryers.
  • Compressed Air Dryer
  • Compressed Air Dryer
Compressed Air Dryer

Compressed Air Dryer

Rs 40,000  / UnitGet Best Price

Product Brochure

Usage/ApplicationIndustrial
BrandSonitech
Minimum Output Dew Point40 Degree C
Warranty12 months
Frequency50 Hz
PhaseThree Phase
MaterialMS
Automation GradeAutomatic
Power SourceElectric
Country of OriginMade in India
Voltage220 V
Capacity200 CFM

Sonitech India Cooling Towers (bottle shape design, FRP induced) are known for superior design and technology. Our Cooling Tower has been designed to meet the high standards demanded by engineers, who require a compact, heavy duty and efficient cooling tower with a long service life and an aesthetic design. Proven in many industries for over 2 decades, these towers have an advantage of compactness and are extensively used in many industries and in HVAC applications.

Being round, the air flow through the Draught Cooling tower is more evenly distributed. Structural members do not interrupt air intake and therefore they have been proven to be thermo- dynamically the most efficient design in the field. This translated directly into reducing running costs. The tower offers PVC fills and eliminators in a design that maximizes economy and efficiency. The counter flow design facilitates low pump heads. The water is distributed inside the tower over the fill area through the self rotating sprinkler so as to give an even distribution over the complete fill area.

DESIGN

FRP Cooling Towers are of vertical induced draught counter flow design with uniform water distribution and optimal heat transfer. Cooling towers can be installed independent of wind velocity

AXIAL FAN

Especially designed energy efficient fans are induced draught axial type with adjustable pitch. Fan blades pitch is factory set and dynamically balanced.

CASING

The tower is made of tough fiberglass reinforced plastic (FRP induced cooling towers) and has sufficient structural strength to withstand high wind velocity and vibrations. Gel coat is used for UV rays protection and longer life. The water sump is also of FRP and is leak proof.

FILL

 

The fill is of rigid poly vinyl chloride (PVC) and is of honey come design with very large contact surface area. The purpose of fill is to split the water and air into several streams to increase the time of contact and also heat transfer between air and water. The fills are available with standard size of 24” x 12” x 6” with the thickness of 0.25 mm.

MOTORS

The motors are totally enclosed (IP-55) flange type, 415 V, 50Hz., induction weather proof with extended shaft and are especially designed for cooling towers.

DRIFT ELIMINATORThe FRP (induced) eliminator attached to the sprinkler reduces the drift loss of water and it is made of rigid PVC material.

SPRINKLER

Sprinklers are available in Brass/ SS/ Alimunium / PVC and the sprinkler pipe distributes the hot water over the entire space of the fill area. Sprinkler pipes are non- clogging and require low pressure to operate and assures uniform water flow.

 

View Complete details

get quote request a call back
Refrigerated Air Dryers

Refrigerated Air Dryers

Rs 35,000  / UnitGet Best Price

Product Brochure

BrandSonitech
Usage/ApplicationIndustrial
MaterialMild Steel
Automation GradeAutomatic
Voltage440 V
Dryer TypeRefrigeration Dryer
Capacity160 CFM
Warranty12 months
PhaseThree Phase
Country of OriginMade in India
Frequency50 Hz

Sonitech India Cooling Towers (bottle shape design, FRP induced) are known for superior design and technology. Our Cooling Tower has been designed to meet the high standards demanded by engineers, who require a compact, heavy duty and efficient cooling tower with a long service life and an aesthetic design. Proven in many industries for over 2 decades, these towers have an advantage of compactness and are extensively used in many industries and in HVAC applications.

Being round, the air flow through the Draught Cooling tower is more evenly distributed. Structural members do not interrupt air intake and therefore they have been proven to be thermo- dynamically the most efficient design in the field. This translated directly into reducing running costs. The tower offers PVC fills and eliminators in a design that maximizes economy and efficiency. The counter flow design facilitates low pump heads. The water is distributed inside the tower over the fill area through the self rotating sprinkler so as to give an even distribution over the complete fill area.

DESIGN

FRP Cooling Towers are of vertical induced draught counter flow design with uniform water distribution and optimal heat transfer. Cooling towers can be installed independent of wind velocity

AXIAL FAN

Especially designed energy efficient fans are induced draught axial type with adjustable pitch. Fan blades pitch is factory set and dynamically balanced.

CASING

The tower is made of tough fiberglass reinforced plastic (FRP induced cooling towers) and has sufficient structural strength to withstand high wind velocity and vibrations. Gel coat is used for UV rays protection and longer life. The water sump is also of FRP and is leak proof.

FILL

 

The fill is of rigid poly vinyl chloride (PVC) and is of honey come design with very large contact surface area. The purpose of fill is to split the water and air into several streams to increase the time of contact and also heat transfer between air and water. The fills are available with standard size of 24” x 12” x 6” with the thickness of 0.25 mm.

MOTORS

The motors are totally enclosed (IP-55) flange type, 415 V, 50Hz., induction weather proof with extended shaft and are especially designed for cooling towers.

DRIFT ELIMINATORThe FRP (induced) eliminator attached to the sprinkler reduces the drift loss of water and it is made of rigid PVC material.

SPRINKLER

Sprinklers are available in Brass/ SS/ Alimunium / PVC and the sprinkler pipe distributes the hot water over the entire space of the fill area. Sprinkler pipes are non- clogging and require low pressure to operate and assures uniform water flow.

 

View Complete details

get quote request a call back
Desiccant Air Dryers

Desiccant Air Dryers

Rs 30,000  / UnitGet Best Price

Product Brochure

Automation GradeAutomatic
Capacity150 CFM
Voltage220 V
Minimum Output Dew Point40 Degree C
BrandSonitech
Country of OriginMade in India
Frequency50 Hz
PhaseThree Phase
Power SourceElectric
MaterialMS
Usage/ApplicationIndustrial

Sonitech India Cooling Towers (bottle shape design, FRP induced) are known for superior design and technology. Our Cooling Tower has been designed to meet the high standards demanded by engineers, who require a compact, heavy duty and efficient cooling tower with a long service life and an aesthetic design. Proven in many industries for over 2 decades, these towers have an advantage of compactness and are extensively used in many industries and in HVAC applications.

Being round, the air flow through the Draught Cooling tower is more evenly distributed. Structural members do not interrupt air intake and therefore they have been proven to be thermo- dynamically the most efficient design in the field. This translated directly into reducing running costs. The tower offers PVC fills and eliminators in a design that maximizes economy and efficiency. The counter flow design facilitates low pump heads. The water is distributed inside the tower over the fill area through the self rotating sprinkler so as to give an even distribution over the complete fill area.

DESIGN

FRP Cooling Towers are of vertical induced draught counter flow design with uniform water distribution and optimal heat transfer. Cooling towers can be installed independent of wind velocity

AXIAL FAN

Especially designed energy efficient fans are induced draught axial type with adjustable pitch. Fan blades pitch is factory set and dynamically balanced.

CASING

The tower is made of tough fiberglass reinforced plastic (FRP induced cooling towers) and has sufficient structural strength to withstand high wind velocity and vibrations. Gel coat is used for UV rays protection and longer life. The water sump is also of FRP and is leak proof.

FILL

 

The fill is of rigid poly vinyl chloride (PVC) and is of honey come design with very large contact surface area. The purpose of fill is to split the water and air into several streams to increase the time of contact and also heat transfer between air and water. The fills are available with standard size of 24” x 12” x 6” with the thickness of 0.25 mm.

MOTORS

The motors are totally enclosed (IP-55) flange type, 415 V, 50Hz., induction weather proof with extended shaft and are especially designed for cooling towers.

DRIFT ELIMINATORThe FRP (induced) eliminator attached to the sprinkler reduces the drift loss of water and it is made of rigid PVC material.

SPRINKLER

Sprinklers are available in Brass/ SS/ Alimunium / PVC and the sprinkler pipe distributes the hot water over the entire space of the fill area. Sprinkler pipes are non- clogging and require low pressure to operate and assures uniform water flow.

 

View Complete details

get quote request a call back
Refrigerated Air Dryers

Refrigerated Air Dryers

Rs 35,000  / UnitGet Best Price

Minimum Order Quantity: 1 Unit

Product Brochure

Dryer TechnologyRefrigerated
Automation GradeAutomatic
Dryer TypeRefrigeration Dryer
Capacity20 CFM to 5000 CFM
Drying Capacity0-20 cfm, 21 - 50 cfm, 121 - 500 cfm, 51 - 120 cfm, 501 - 1000 cfm
Maximum Pressure<2 bar, 4 bar, 8 bar, 12 bar, >14 bar, 10 bar, 7 bar, 14 bar
Dryer BrandSONITECH
Minimum Output Dew Point-20 C
RefrigerantR22/ R407C/R134a
Warranty12 months
ISO Class90012015
BrandSONITECH
ConditionNew
Installation/After Sales Service AvailableYes

We are identified as one of the most reputed Refrigerated Compressed Air Dryer manufacturers. We provide Refrigerated Air Dryers Using Freon Gas. The superior Refrigerated Air Dryer System provided by us is extremely effective to purify impure compressed air that contains dust, oil, and moisture.


AIR Drying:
These are two basic modes of removal of moisture (drying of air) from compressed air:
  • Adsorption drying.
  • Refrigeration drying.

    Adsorption Drying:
    • It works on basic principle of mass transfer i.e. adsorption of moisture from compressed air by desiccant like Silica Gel, Activated Alumina or Molecular Sieves. These types of air dryers are economical when extremely dry air having atmospheric dew point of -40oC or lower is required.

      Refrigeration Drying:

      • It works on the principle of cooling down air to 3oC by a suitable refrigerant like freon, NH3 Etc. Refrigerated dryers are the best choice for instrument-air applications. We are expertise in design and manufacture of both the above types of air dryer and depending upon the ultimate use, we can offer suitable dryer, duly selected and designed to meet your specific need.

       

      Specifications:

      ModelRated Capacity in CFM
      Standard refrigerant HPAir Inlet/Outlet ConnectionApprox. Dimensions in mmApprox. weight in kgs
      RAD-1-A100.1615 BSP600 X 400X 40050
      RAD-2-A200.2515 BSP750 X 500 X 60060
      RAD-5-A500.3320 BSP900 X 500 X 60070
      RAD-10-W1000.7525 BSP1100 X 500 X 600100